10 exam-style questions with answers and explanations, straight from our 1,050-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
These 10 free CFPE questions are organized by exam domain, so you can see how each part of the Certified Fire Plan Examiner blueprint is tested. Reveal the answer and explanation under each question.
Domain 1: Administration 21% of exam
Question 1
A jurisdiction has formally adopted the 2021 edition of NFPA 101. A designer submits plans citing a 2024 edition provision that is MORE stringent than the 2021 requirement. How should the plan examiner proceed?
Show answer & explanation
Correct answer: D - Apply the 2021 edition, since the adopted edition governs in the jurisdiction
Question 2
A design professional proposes an alternative material not specifically addressed by the adopted code, asserting it provides equivalent protection. Under the equivalency provisions, who carries the burden of demonstrating equivalency?
Show answer & explanation
Correct answer: A - The submitter proposing the alternative material
Question 3
A plan examiner identifies a dead-end corridor that exceeds the permitted length. Which comment is MOST appropriate for the plan review report?
Show answer & explanation
Correct answer: B - "Dead-end corridor at grid line 4 exceeds the limit of the applicable occupancy chapter; cite section provided."
Domain 2: Plan Review 79% of exam
Question 4
A plan examiner receives a complete set of construction documents for a new building. Which determination must be made FIRST, because every subsequent code requirement depends on it?
Show answer & explanation
Correct answer: C - Determine the occupancy classification of the building and its spaces
Question 5
When calculating occupant load, which of the following is the defining characteristic of NET floor area as opposed to GROSS floor area?
Show answer & explanation
Correct answer: A - Net area excludes corridors, stairs, restrooms, and mechanical spaces; gross area includes them
Question 6
A single-story building contains 6,000 ft² of open office area (150 ft² gross/person) and a 1,200 ft² conference room with tables and chairs (15 ft² net/person). What is the total occupant load, and which space governs it?
Show answer & explanation
Correct answer: B - 120 persons; the conference room governs despite being the smaller space
Question 7
A candidate is asked to verify the maximum permitted travel distance for a space. What is the correct approach?
Show answer & explanation
Correct answer: B - Locate the limit in the occupancy chapter applicable to that specific occupancy and status
Question 8
A developer submits plans for a five-story apartment building with sprinkler protection designed to NFPA 13R. The plan examiner should:
Show answer & explanation
Correct answer: C - Identify a deficiency, because NFPA 13R is limited by the building's height in stories
Question 9
A building contains manufacturing operations and administrative offices that are intermingled throughout, with no fire-resistance-rated separation between them. How are the code requirements applied?
Show answer & explanation
Correct answer: C - The requirements applicable to the most restrictive occupancy present are applied
Question 10
A floor has an occupant load of 300 persons egressing entirely by stairways, using a capacity factor of 0.3 in. per person. Two stairways are provided. What total stair width is required, and what must the examiner ALSO verify?
Show answer & explanation
Correct answer: D - 90 in. total; that each stairway independently meets the minimum required width
That's 10 of 1,050
The full bank has 1,040 more CFPE questions with explanations.